This explanation makes it clear that an insulating tool is necessary to maintain an employee at a safe distance when installing or removing grounds. OSHA will consider any device that is insulated for the voltage and allows an employee to apply or remove the ground from a safe position, to be a live line tool for the purposes of 1910.269(n)(6) and (n)(7). The Agency agrees with these commenters, and has adopted their suggestion in the final rule. They noted that it is unsafe for an employee to be too close, when connecting or disconnecting a ground, and urged OSHA to eliminate the phrase "or other insulated devices" from the rule.
Fantasy grounds 2 rule sets install#
Several commenters were concerned that this language implied that rubber gloves could be used to install and remove grounds. The preamble summary and explanation section to this rule ( Federal Register 59(20), Monday, January 31, 1994, p. Question #1: Is it acceptable to apply personal protective grounds without a live line tool by hand using rubber glove methods while protecting line personnel with class II rubber gloves and sleeves, flame retardant upper body clothing, UV protective safety glasses with side shields and a face shield without using a live line tool? Paragraphs (n)(6) and (n)(7) are clear regarding the application of grounds using a tested live line tool, however (n)(2) offers grounding alternatives. The small size of the high seal end, the weight of the ground, and the ground wire conductor, typically #2 or #4/0 copper, make this impractical. When this lead is removed, applying grounds with a live line tool is nearly impossible due to the instability of the lead. This is accomplished using rubber-gloving methods.
![fantasy grounds 2 rule sets fantasy grounds 2 rule sets](https://img.gg.deals/32/2e/10440dbb10028e1df5df37d98565b6f01821_912cr485.jpg)
![fantasy grounds 2 rule sets fantasy grounds 2 rule sets](https://steamcdn-a.akamaihd.net/steam/apps/300790/ss_60c47f735624fec6de5f36e23eca24286d6b3559.1920x1080.jpg)
Internal operating procedures require either the line or load side leads to the disconnect be removed in order for the open disconnect to be an acceptable energy isolating point. These are connected to and used to isolate underground cables as per paragraph (m). Your background information, questions, and our responses follow:īackground: Niagara Mohawk has 5kV porcelain enclosed disconnect switches on riser poles, installed throughout its service territory. You have questions regarding the application of personal protective grounds, for the protection of employees, as required in the Electrical Power Generation, Transmission, and Distribution Standard, 29 CFR §1910.269. Thank you for your Augletter to the Occupational Safety and Health Administration's (OSHA's) Directorate of Compliance Programs.